Relay Symbols and Electromagnets
The relay are switching electrical devices activated by signals. Most of the time, a small voltage or current is used to switch other voltages or higher currents that may be electromechanical or fully electronic type.
The electromagnetic controls are activated thanks to electromagnetic fields generated by electricity.
Symbol | Description | Symbol | Description | |
---|---|---|---|---|
Relay (Coil) Generic symbol |
Relay (Coil) Generic symbol |
|||
Relay | Double coil relay | |||
Double coil relay | Two operating relay windings in opposite directions | |||
Double coil relay | Overcurrent relay | |||
Fast deactivation relay | Differential current relay | |||
Slow excitation relay | Slow deactivation relay | |||
High speed relay, for both the connection and the disconnection | Maximum voltage relay | |||
Fast relay | Relay actuated by defective voltage | |||
Card operated relay | Relay not affected by AC | |||
Differential relay | Polarized relay + Info |
|||
Magnetically polarized relay | Delayed action relay on disconnection | |||
Electromagnetic relay | Thermo-relay Thermal relay |
|||
Solid-state relay Electronic relay + Info |
Stepping or pulse relay | |||
Remote control relay | Pulse relay | |||
Remnant relay | Intermittent relay | |||
Relay remnant | Electric valve / Solenoid valve + Info |
|||
AC relay | Relay rest with delayed operation | |||
Relay mechanical resonance e.g. 25Hz |
Step relay Mechanical interlock relay |
|||
Relay with light pilot | ||||
Measuring Relay Symbols |
||||
Maximum voltage relay | Minimun voltage relay | |||
Low impedance relay | Relay of voltage absence | |||
Detection relay with divided conductor | Low power relay | |||
Detector relay of short-circuit between coils | Reverse current relay | |||
Detector relay of failure in tri-phasic lines | Maximun and minimun current relay | |||
Relay blocked rotor | Frequency relay | |||
Automatic reclosing relay | Overcurrent relay with two measuring elements and a range of sample e.g. 1...5A sample range |
|||
Overcurrent relay with delayed action | Measuring relay The asterik is replaced by letters or symbols related to the relay |
|||
Electromagnet Symbols / Electromagnetic Controls |
||||
Electromagnet Electromagnetic drive + Info |
Electromagnet | |||
Electromagnet Electromagnetic drive US Symbol |
Contact with electromagnetic anchoring mechanism | |||
Reed relay / Reed switch + Info |
||||
Symbols of Relay Contacts |
||||
Open contacts NO - Normally open + Info |
Closed contacts NC - Normally closed |
|||
Open contacts NO - Normally open |
Closed contacts NC - Normally closed |
|||
Open contacts NO - Normally open |
Closed contacts NC - Normally closed |
|||
Contacts work | Contacts resting | |||
Switching contacts | Switch contacts successive | |||
Commutator / Switch | Commutator / Switch | |||
Relay device symbols with contacts |
||||
Relay / solenoid operated (Coil and Switch) Generic symbol + Info |
Relay / solenoid operated | |||
Relay / solenoid operated | Relay / solenoid operated Coil and pushbutton |
|||
Relay switch | Contactor | |||
Relay - SPST Single pole, single throw |
Relay - SPDT Single pole, double thorw |
|||
Relay - DPST Double pole, single thorw |
Relay - DPDT Double pole, double thorw |
|||
Relay - DPST Double pole, single thorw |
Relay - 3PDT Three pole, double thorw |
|||
Relay - 3PST Three pole, single thorw |
||||
Picture gallery of relays and electromagnetsDownload symbols |